Sampling. Sampling for examination shall be conducted in accordance with MIL-STD-105 and table I. The unit of product for sampling purposes shall be one roll of identification markers as specified in this description.
TABLE I. Sampling for examination.
|
Inspection level |
AQL (defects per hundred units) |
For visual examination |
|
|
Major defects |
II |
1.0 |
Total defects (Major and minor combined) |
II |
4.0 |
For dimensional examination |
S-1 |
2.5 |
Examination. The identification marker roll shall be examined to determine compliance with all requirements contained in this specification.
Classification of defects. Examination shall be conducted in accordance with the classification of defects listed in table II. Examinations shall be restricted to the classified possible defects below.
TABLE II. Categories and Defects.
Categories |
Defects |
Major |
|
101 |
Label does not have correct numeral color or background color. |
102 |
Adhesive does not provide a permanent attachment to the x-ray folder. |
103 |
Numeral not printed twice on each label. |
104 |
Numeral not printed parallel and adjacent to the left and right margins of the label. |
105 |
Label mylar coated. |
106 |
Roll does not contain 1000 labels. |
Minor |
|
201 |
Label not clean |
202 |
Label colors faded or inconsistent. |
Dimensional Examination. The identification marker shall be examined for defects in dimensions. Any dimension not within the specifications herein shall be classified as a defect.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business